Aplicación de la Teoría de Perturbación – Método Diferencial- al Análisis de Sensibilidad en Generadores de Vapor de Centrales Nucleares PWR-Caso Angra I

Authors

  • Giol Sanders R y Cols.

DOI:

https://doi.org/10.33017/RevECIPeru2011.0033/

Keywords:

perturbation theory, differential method, steam generator, PWR nuclear Power Plant.

Abstract

This report presents an application of the differential approach of the perturbation theory to an homogeneous model of a PWR steam generator in the Angra 1 Nuclear Power Plan in Brazil under steady-state conditions. Program PERGEVAP was built fom the code GEVAP developed by Souza and allows sensitivity calculations of linear (average primary loop temperature) and non-linear (average heat flux) functionals due to variations in some thermo-hydraulics parameters (flow rate, specific heat, , etc). Results obtained with this approach are then compared with direct calculations performed using the GEVAP code, with excellent agreements. The method has good potential to treat repeated calculations needed in the design and safety analysis of the Nuclear Plant components.

Published

2019-01-12

Issue

Section

ARTÍCULOS ORIGINALES